In the last 6 years, hospitals in developed countries have been trialling the use of command centres for improving organizational efficiency and patient care. However, the impact of these command centres has not been systematically studied in the past. It is a retrospective population-based study. Participants were patients who visited the Bradford Royal Infirmary hospital, Accident and Emergency (A&E) Department, between 1 January 2018 and 31 August 2021. Outcomes were patient flow (measured as A&E waiting time, length of stay, and clinician seen time) and data quality (measured by the proportion of missing treatment and assessment dates and valid transition between A&E care stages). Interrupted time-series segmented regression and process mining were used for analysis. A&E transition time from patient arrival to assessment by a clinician marginally improved during the intervention period; there was a decrease of 0.9 min [95% confidence interval (CI): 0.35–1.4], 3 min (95% CI: 2.4–3.5), 9.7 min (95% CI: 8.4–11.0), and 3.1 min (95% CI: 2.7–3.5) during ‘patient flow program’, ‘command centre display roll-in’, ‘command centre activation’, and ‘hospital wide training program’, respectively. However, the transition time from patient treatment until the conclusion of consultation showed an increase of 11.5 min (95% CI: 9.2–13.9), 12.3 min (95% CI: 8.7–15.9), 53.4 min (95% CI: 48.1–58.7), and 50.2 min (95% CI: 47.5–52.9) for the respective four post-intervention periods. Furthermore, the length of stay was not significantly impacted; the change was −8.8 h (95% CI: −17.6 to 0.08), −8.9 h (95% CI: −18.6 to 0.65), −1.67 h (95% CI: −10.3 to 6.9), and −0.54 h (95% CI: −13.9 to 12.8) during the four respective post-intervention periods. It was a similar pattern for the waiting and clinician seen times. Data quality as measured by the proportion of missing dates of records was generally poor (treatment date = 42.7% and clinician seen date = 23.4%) and did not significantly improve during the intervention periods. The findings of the study suggest that a command centre package that includes process change and software technology does not appear to have a consistent positive impact on patient safety and data quality based on the indicators and data we used. Therefore, hospitals considering introducing a command centre should not assume there will be benefits in patient flow and data quality.
Received 2022 Aug 24; Revised 2023 May 25; Accepted 2023 Sep 15; Collection date 2023 Oct.
The introduction of electronic health records has improved the patient care delivery process and quality of care, mainly through the easy access to comprehensive and rich patient data for research as well as minimizing medical errors [
The fragmentation of healthcare services is neither cost-effective nor safe for the delivery of patient care [
In the UK, command centres are currently being trialled in four NHS hospital trusts, including Bradford Teaching Hospitals NHS Foundation Trust. In 2019, the Bradford Teaching Hospitals NHS Foundation Trust introduced a command centre at the Bradford Royal Infirmary hospital [
Bradford is the seventh largest metropolitan district in England and Wales with a population of over half a million. It is ethnically diverse, with 56.7% identifying as of White British origin, and 25.5% identifying as of Pakistani origin. The population consists of 25.8% aged <18 years and 74.2% aged ≥18 years (
The study included patients who visited the Bradford Royal Infirmary hospital between 1 January 2018 and 31 August 2021. This was a period in which the command centre was introduced through a number of phases immediately prior to the coronavirus disease (COVID-19) pandemic.
This is a retrospective population-based cohort study undertaken as part of a mixed-methods evaluation project with a formal evaluation protocol published by the authors in January 2022 [
Project timeline and intervention phases.
Data from the hospital’s Secondary Use Services data were provided by the Connected Bradford data service [
Public and patient representatives were consulted throughout the study period through workshops at the command centre. Representatives contributed to the development of the research protocol [
A range of patient flow and data quality outcome indicators were identified in the study protocol [
In-patient length of stay in emergency admissions (defined as the duration between date and time of admission and discharge), ‘clinician seen time’ [the duration between accident and emergency (A&E) time of arrival and the time seen by a clinician] and A&E waiting time (the duration between A&E time of arrival and time of treatment) were used as indicators for weekly patient flow metrics throughout the study period. In addition, average times taken between A&E transitions (arrival, assessment, treatment, visit conclusion, and checkout) were used as indicators for patient flow metrics during the same period.
The proportion of missing dates of treatment and clinician’s assessment for A&E patients were used as indicators for weekly data quality metrics throughout the study period. In addition, the proportions of records showing valid transition of patients in A&E care (arrival → assessment → treatment → visit conclusion → checkout) were also used.
Dummy variables were created for each of the intervention components—‘onset of patient flow program’, ‘command centre displays roll-in’, ‘command centre activation’, and ‘hospital wide engagement and training’. We also identified the onset of the COVID-19 pandemic and subsequent spikes in its impact [
A continuous incremental time variable was coded from the start of the time series (e.g. 1, 2, 3, 4). The intervention phases were also modelled using five continuous time variables with ‘0’ in the pre-intervention period, ‘1, 2, 3, 4…’ from the onset of the intervention phase until the end of the phase then level-off for the rest of the study. In addition, seasonality was modelled by including dummy variables for the number of weeks in a year.
Interrupted times-series linear regression analysis [
To estimate the average transition time between different stages of A&E care and to map the destinations of A&E patients, a process-mining technique was used [
A five-phase interrupted time series was used for the main analyses. To explore if the technology alone had an impact on outcomes, a three-phase interrupted time-series model was used as sensitivity analysis. The ‘broad patient flow program’ and ‘hospital wide engagement and training’ were assumed as independent events of the command centre and adjusted as independent dummy variables in sensitivity analysis models. Five percent significance level and 95% confidence intervals (CIs) were adopted throughout. Analyses were implemented in R (Version 4.0.2).
A total of 203 807 inpatients and 197 084 A&E visits were included in the study.
The overall weekly average length of stay for emergency admission patients remained between 70 and 90 h for much of the period between January 2018 and December 2019. It sharply increased to 105 h during the first week of January 2020 and then dropped to and stayed on ∼80 h until the end of February 2020. It then steadily increased starting from March 2020 until January 2021 and then showed a steady decrease until the end of the study period. Overall, there appears to be a higher average length of stay during the COVID-19 pandemic than the pre-pandemic period (see
A weekly pattern of patient flow and data quality indicators during the study period (vertical dashed lines are the interrupts).
The weekly average ‘clinician seen time’ (time from arrival until assessed by a clinician) stayed <1 h throughout the study period (see
The average transition time between A&E care stages was largely similar in the pre-intervention and post-intervention periods except that there was a significant increase in the transition time from treatment to conclusion of the visit during the ‘command centre going live’ and ‘hospital wide engagement and training’ periods (see
Overall, the weekly proportion of missing clinician seen dates and treatment dates was 23.4% (range = 20.8–28.5%) and 42.7% (range = 14.7–53.5%), respectively. The weekly proportion of missing clinician seen dates ranged between 12% and 34% during the follow-up period. Although it remained between 20% and 30% for the majority of the study period, there was a moderate decrease between March and May 2020. On the other hand, the weekly proportion of missing treatment dates showed a steady increase from January 2018 (30%) until February 2020 (67%), which then sharply decreased to ∼25% in March 2020 before a sharp increase to >75% in August–December 2020 (see
The proportions of A&E visits progressing to the next ‘valid’ stage of care remained similar among the pre-intervention and post-intervention periods. Visits with records of consultation conclusion time were most likely (>92%) to have their checkout time recorded in all intervention periods. Visits with assessment time recorded were least likely (28–70%) to have their treatment time recorded for the same period, see
There was no significant difference in the weekly average length of stay of admitted patients between the pre-intervention period and the post-intervention period. The A&E waiting times (time from arrival until patient received treatment) showed an increase of 62 min (95% CI: 40–85 min) during the fourth (‘hospital wide engagement resumption’) intervention period when compared with the pre-intervention period. The first and second intervention periods also showed a decrease of 10 min (95% CI: 4–16 min) and 9 min (95% CI: 2–15 min) in the average A&E clinician seen time when compared with the pre-intervention period (see
Summary results for five-phase models.
| Outcome | Intervention phase | Change (95% CI) |
|---|---|---|
| Length of stay (h) | Pre-intervention | Reference |
| Patient flow programme | −8.8 (−17.6 to 0.08) | |
| Command centre display roll-in | −8.9 (−18.6 to 0.65) | |
| Command centre activation | −1.67 (−10.3 to 6.9) | |
| Engagement resumption | −0.54 (−13.9 to 12.8) | |
| Waiting time (h) | Pre-intervention | Reference |
| Patient flow programme | −0.14 (−0.39 to 0.11) | |
| Command centre display roll-in | −0.21 (−0.48 to 0.06) | |
| Command centre activation | −0.19 (−0.43 to 0.06) | |
| Engagement resumption | 1.04 (0.67 to 1.42) | |
| Clinician seen time (h) | Pre-intervention | Reference |
| Patient flow programme | −0.16 (−0.26 to −0.06) | |
| Command centre display roll-in | −0.14 (−0.25 to −0.04) | |
| Command centre activation | −0.06 (−0.16 to 0.03) | |
| Engagement resumption | 0.0 1 (−0.14 to 0.15) | |
| Clinician seen date missing (%) | Pre-intervention | Reference |
| Patient flow programme | −1.5 (−4.75 to 1.76) | |
| Command centre display roll-in | −0.85 (−4.38 to 2.69) | |
| Command centre activation | 0.44 (−2.72 to 3.60) | |
| Engagement resumption | 17.2 (12.26 to 22.10) | |
| Treatment date missing (%) | Pre-intervention | Reference |
| Patient flow programme | 3.0 (−8.37 to 14.38) | |
| Command centre display roll-in | 10.2 (−2.16 to 22.54) | |
| Command centre activation | 21.5 (10.4 to 32.5) | |
| Engagement resumption | 2.3 (−14.8 to 19.5) |
Models were adjusted for trends, the COVID-19 pandemic (pre- and post-pandemic), and COVID-19 spikes.
Inpatient emergency admissions.
A&E visits.
The transition time from arrival to assessment consistently improved during the intervention period; there was a decrease of 0.9 min (95% CI: 0.35–1.4), 3 min (95% CI: 2.4–3.5), 9.7 min (95% CI: 8.4–11.0), and 3.1 min (95% CI: 2.7–3.5) during ‘patient flow program’, ‘command centre display roll-in’, ‘command centre activation’, and ‘hospital wide training program’, respectively. However, the transition time from assessment, treatment, and visit conclusion to the next respective A&E stage of care had worsened significantly during the intervention periods. For example, the transition time from patient treatment until the conclusion of consultation showed an increase of 11.5 min (95% CI: 9.2 –13.9), 12.3 min (95% CI: 8.7–15.9), 53.4 min (95% CI: 48.1–58.7), and 50.2 min (95% CI: 47.5–52.9) during ‘patient flow program’, ‘command centre display roll-in’, ‘command centre activation’, and ‘hospital wide training program’, respectively (
A summary of changes in the average A&E transition time.
| Average transition time (min) [Mean (95% CI)] | ||||
|---|---|---|---|---|
| Intervention phase | Arrived → assessed | Assessed → treated | Treated → concluded | Concluded → checked out |
| Pre-intervention | Reference | Reference | Reference | Reference |
| Patient flow | −0.9 (−1.4 to −0.35) | 5.9 (3.9 to 7.9) | 11.5 (9.2 to 13.9) | 14.0 (−33.1 to 5.2) |
| CC display roll-in | −3.0 (−.3.5 to −2.4) | 4.7 (2.3 to 7.1) | 12.3 (8.7 to 15.9) | 4.1 (2.8 to 5.4) |
| CC activation | −9.7 (−11.0 to −8.4) | −21.0 (−23.1 to −18.9) | 53.4 (48.1 to 58.7) | 0.9 (−1.2 to 3.0) |
| HW training | −3.1 (−3.5 to −2.7) | 10.2 (8.1 to 12.3) | 50.2 (47.5 to 52.9) | −0.4 (−2.4 to 1.6) |
CC, command centre; HW, hospital wide.
The data quality did not change significantly during the study period, except that the weekly proportion of missing clinician seen dates significantly worsened during the ‘hospital wide engagement resumption’ period when compared with the pre-intervention period (change = 17%; 95% CI: 10.4–32.5%). Likewise, there was a significant increase in the weekly proportion of missing treatment dates during the ‘command centre activation’ period when compared with the pre-intervention period (see
The proportion of arrivals and patients with their consultation closed (or recorded as ‘concluded visits’) that progressed to the next ‘valid’ stage of A&E care (i.e. assessment and checkout, respectively) had largely improved during the intervention period. For example, there was an increase in the proportion of patients who arrived in the A&E and assesses by a clinician improved by 2.4%, 3.0%, and 3.7% during the ‘patient flow’, ‘command display roll-in’, and ‘hospital wide engagement resumption’ periods, respectively (see
A summary of changes in the proportion of A&E visits following ‘rules’.
| Changes in the proportion of A&E activities following ‘rules’ (95% CI) | ||||
|---|---|---|---|---|
| Intervention phase | Arrived → assessed | Assessed → treated | Treated → concluded | Concluded → checked out |
| Pre-intervention | Reference | Reference | Reference | Reference |
| Patient flow | 2.4 (1.7 to 3.2) | −3.7 (−4.8 to −2.6) | −1.5 (−2.4 to −0.7) | 1.5 (0.9 to 2.1) |
| CC display roll-in | 3.0 (2.3 to 3.8) | −18.1 (−19.3 to −16.9) | −8.0 (−9.1 to −6.9) | 3.2 (2.7 to 3.8) |
| CC activation | −0.0 (−0.0 to 0.0) | −32.6 (−33.5 to −31.7) | −25.7 (−26.5 to 25.0) | −0.5 (−0.9 to −0.0) |
| HW training | 3.7 (3.1 to 4.3) | 9.3 (8.4 to 10.2) | −11.4 (−12.0 to −10.7) | 3.7 (3.2 to 4.1) |
CC, command centre; HW, hospital wide.
When only the technology was assumed as part of the intervention, there was no meaningful difference between the pre- and post-intervention periods in the patient flow indicators (length of stay, waiting time, and clinician seen time). For example, the changes in the length of stay during the ‘command centre display roll-in’ and ‘command centre activation’ intervention periods were −4.39 h (95% CI: −16.1 to 7.3) and 3.2 h (95% CI: −7.6 to 14.0), respectively (see
In this pre- and post-intervention comparative study using time-series data from the hospital’s information systems, the findings indicate that the introduction of the command centre, including software technology and process changes, or the software technology alone had no significant and consistent measurable impact on patient flow and data quality. Based on patient flow indicators, the length of stay showed a nonsignificant decrease of 8.8 h [standard error (SE): 4.5], 8.9 h (SE: 4.9), 1.7 h (SE: 4.4), and 0.55 h (SE: 6.8). The waiting time (time taken until patient treatment), clinician seen time (time until patient is seen by a clinician), and A&E transition time (time taken to progress from one stage of A&E care to the next stage of A&E care) also did not significantly improve during the study period.
The data quality also was worse when the command centre was introduced. On average, the proportion of missing treatment dates and clinician seen dates was 42.7% and 23.4%, respectively. In comparison to the pre-intervention period, the proportion of A&E visitor’s missing treatment dates was higher by 3% (SE: 45.8), 10.2% (SE: 6.3), 21.5% (SE: 5.6), and 2.3% (SE: 8.7) when a ‘patient flow program’, ‘command centre display roll-in’, ‘command centre activation’, and ‘hospital wide engagement resumption’ programmes were implemented, respectively.
There is a paucity of studies that investigate the impact of multidepartment hospital–based command centres on patient flow and data quality. A recent study in Saudi Arabia reported that the use of a ‘smart centre’ led to a reduction of intensive care unit lengths of stay by 10% in emergency admissions [
The Johns Hopkins Hospital in Baltimore, USA also reported reduction in time for ambulance dispatches and bed allocation for emergency department–admitted patients [
Our study has certain limitations. First, health service delivery was significantly affected by the COVID-19 pandemic resulting in rapid system-wide effects, which may have an impact on the population of patients and capacity management in the hospital. Cancellation and postponement of surgical operations were common due to the reallocation of resources during the peaks of the pandemic. Although we attempted to control for the effects of the pandemic in our time-series models, the proximity of the activation of the command centre with the onset of the pandemic surge makes it difficult to isolate the effect of the intervention.
Another potential limitation of the study concerns the focus of this quantitative evaluation on a small number of outcome indicators for what was a system-wide initiative designed to impact many areas. Although informing our intervention models using qualitative research at the study site was a strength in our design, qualitative investigation additionally revealed the complexity of this type of intervention and the challenges of implementation within a pressured acute care environment. This may have influenced the study outcome in a number of ways. Staff recall of the historical implementation timeline was variable, especially for the piloting and roll-in of intervention components, including organizational in addition to technological elements. There were suggestions that the colocation of staff in the command centre room that preceded the roll-in and activation phase for command centre displays may have already been established and coordinating functions sooner than the intervention timeline suggests, leading to under-specification of our model. When considering the challenges observed in implementing the technological aspects of the intervention, including data quality, there may have been a significant time lag between the activation of components and any impact on patient flow outcomes. Given the complexity of our intervention model, we did not seek to control for lagged effects of intervention implementation (the time it takes for an intervention to start to influence detectable outcomes). Rather, we presumed that the effects of the intervention components were instantaneous. Finally, due to data access limitations, we could not explore all outcomes identified for analysis in our study protocol.
Nonetheless, the strengths of the study are 3-fold. First, we have used a large sample size for the analyses (203 807 in-patient visits and 197 084 A&E visits). Second, the use of electronic health records data minimizes the inherent biases and errors in other types of observational data. Third, we employed a robust quasi-experimental design using repeated time-series measurement.
Currently, data on the impact of command centres on patient flow and data quality are scarce although the use of these technologies has widely been adopted in the developed world. Our study also has not found strong evidence of the positive impact of these novel technologies on patient flow and data quality outcomes. Therefore, further research using data from other hospital organizations that use the technologies is warranted.
The findings of the study suggest that a command centre package that includes the change of process and software technology does not appear to have a consistent positive impact on patient flow and data quality based on the indicators and data we used. Moreover, when only the software technology was assumed as a component of the intervention, no consistent and significant positive impact on patient flow and data quality was observed. Therefore, hospitals considering introducing a command centre should not assume there will automatically be benefits in patient flow and data quality.
Click here for additional data file.
We thank the Patient and public involvement and engagement (PPIE) representatives for their contribution to the conception, development, ongoing implementation, and future communication of this project.
Teumzghi F Mebrahtu, School of Computing, University of Leeds, Leeds LS2 9JT, UK; Bradford Institute for Health Research, Bradford Teaching Hospitals NHS Foundation Trust, Bradford Royal Infirmary, Duckworth Ln, Bradford BD9 6RJ, UK.
Ciaran D McInerney, School of Computing, University of Leeds, Leeds LS2 9JT, UK; Yorkshire and Humber Patient Safety Translational Research Centre, Wolfson Centre for Applied Health Research, Bradford Royal Infirmary, Duckworth Ln, Bradford BD9 6RJ, UK.
Jonathan Benn, Bradford Institute for Health Research, Bradford Teaching Hospitals NHS Foundation Trust, Bradford Royal Infirmary, Duckworth Ln, Bradford BD9 6RJ, UK; School of Psychology, University of Leeds, Woodhouse Lane, Leeds LS2 9JT, UK.
Carolyn McCrorie, Yorkshire and Humber Patient Safety Translational Research Centre, Wolfson Centre for Applied Health Research, Bradford Royal Infirmary, Duckworth Ln, Bradford BD9 6RJ, UK; School of Psychology, University of Leeds, Woodhouse Lane, Leeds LS2 9JT, UK.
Josh Granger, School of Psychology, University of Leeds, Woodhouse Lane, Leeds LS2 9JT, UK.
Tom Lawton, Bradford Teaching Hospitals NHS Foundation Trust, Bradford Royal Infirmary, Duckworth Ln, Bradford BD9 6RJ, UK.
Naeem Sheikh, Yorkshire and Humber Patient Safety Translational Research Centre, Wolfson Centre for Applied Health Research, Bradford Royal Infirmary, Duckworth Ln, Bradford BD9 6RJ, UK.
Ibrahim Habli, Department of Computer Science, University of York, Heslington, York YO10 5DD, UK.
Rebecca Randell, Wolfson Centre for Applied Health Research, Bradford Royal Infirmary, Duckworth Ln, Bradford BD9 6RJ, UK; Faculty of Health Studies, University of Bradford, Richmond Rd, Bradford BD7 1DP, UK.
Owen Johnson, School of Computing, University of Leeds, Leeds LS2 9JT, UK; Yorkshire and Humber Patient Safety Translational Research Centre, Wolfson Centre for Applied Health Research, Bradford Royal Infirmary, Duckworth Ln, Bradford BD9 6RJ, UK.
This project is funded by the National Institute for Health Research Health Service and Delivery Research Programme (NIHR129483) and the National Institute for Health Research (NIHR) Yorkshire and Humber Patient Safety Translational Research Centre. The views expressed in this article are those of the authors and not necessarily those of the NHS, the NIHR, or the Department of Health and Social Care.
Data pertaining to analysis results are fully available in the main text of the manuscript and the supplementary material file.
J.B., C.M., C.D.M., and O.J. conceptualized the study. T.F.M., J.B., C.M., C.D.M., J.G., N.S., and O.J. contributed to the study design. T.F.M. conducted data extraction, management, analysis, and preparation of the first draft of the manuscript. J.B., C.M., C.D.M., J.G., N.S., I.H., T.L., R.R., and O.J. reviewed the manuscript for important intellectual content. All authors have been involved in revising the work and have approved the final versions for publication.